Chong Qing Gathering Marine Equipment co., Ltd.
|
Price: | 2266.0 USD |
Payment Terms: | T/T,L/C,WU |
Place of Origin: | Chongqing, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Marine Bilge Alarm Oil Content Monitor (15PPM BILGE ALARM)
-Introduction
The OCM-07 type oil-in- water monitor has been designed specifically for use in continuous monitoring of oil-in-condensate or oil-in-boiler feed water without specific environment condition, it is applicable to high water temperature.
The unit is supplied with 2 works-adjusted alarms. The set point (15mg/l) could be adjusted at any moment through the front panel. If an alarm set point is exceed, the alarms are visible at the front panel and the appropriate relays are switched.
Furthermore a 0(4) - 20 mA (equal to 1 30 ppm) signal output is available for driving a recorder or external meter.
1.2 This device is type approved by Q/YNK01-2009 < OCM-series Oil-in-Water Monitor Device Technical Specification>, and it is in accordance with the IMO-Resolution MEPC. 107 (49).
-Measuring Principle
Several optical sensors measures a combination of light scattered and absorbed by oil droplets in the sample stream. The sensor signals are then processed by a microprocessor to produce linearised output. If an alarm occurs, the two oil alarm relays are activated after the adjusted time delay. The microprocessor continuously monitors the condition of the sensor components and associated electronics to ensure that calibration accuracy is maintained over time and extremes of environmental conditions.
-Features
Compact and robust construction
Low maintenance
Small dimensions
Easy installation
Continuous on-line work
Works adjustment
Easy zero adjustment via push buttons (5mg/l)
-Specification
Type: OCM-06OCM-07OCM-08OCM-09
Range: 0 30mg/l 0 9.9mg/l0 99mg/l0 30mg/l
Accuracy Better than 2mg/lBetter than 1mg/lBetter than 2mg/lBetter than 2mg/l
Linearity better than 2 %
Display 2 digits 14 segment LED's
Power Supply: 24 Volt AC/DC ± 10%
Consumption: 5 VA
Alarm Points: Adjustable between 1- 30 mg/l
Alarm Points works set: 10mg/l2mg/l10mg/l15mg/l
Alarm Indication: Red LED's
Output Signal: 0 - 20 mA or 4 - 20 mA, reversible Ri < 500
Sample Water Pressure: 0, 1 - 8bar
Sample Flow: Approx. 0, 5 - 4 l/min depend. To pressure
Ambient Temperature: - 20 to + 55° C
Sample Water Temperature: + 1 to + 100° C
Size (over all): 394mmW× 280mmH× 135mD
Degree of Protection: IP 65
Weight: 5 kg
Pipe Connections: R 1/4" Female